AFRD fire door monitoring system
时间: 2018-10-19 14:33 浏览次数: 来源:金沙网址

  1. Overview of fire door monitoring system

  1.1. Fire door monitoring system setting necessity

  With the rapid development of economy and science and technology, the intensity of urban personnel is constantly increasing. When a fire occurs, the fire source is quickly isolated and the fire range is effectively controlled, which can create favorable conditions for the fire and the evacuation of personnel. Therefore, fireproof partitions such as fire doors are widely used in the fire protection design of construction projects. However, due to unreasonable design, improper selection, and inadequate monitoring, the fire doors cannot fully exert their isolation. Therefore, real-time monitoring and control of the working state of the fire door is an important measure to prevent the spread of fire and the spread of smoke, so the fire door monitoring system came into being.

  The fire door monitoring system is a new product in the field of fire safety. It integrates industrial computer technology, communication, anti-electromagnetic interference, digital sensor technology and industrial field bus control technology into an intelligent system, which can work on the working status of fire doors for 24 hours. Real-time automatic inspection, giving an alarm to the fire door in an abnormal state. In the event of a fire, the surveillance system automatically closes the fire door, gaining valuable time for fire rescue and evacuation.

  With the support of national mandatory regulations, the design and installation of fire doors has become an indispensable part of the construction engineering field. The market demand for fire door monitoring systems is increasing, and the market relationship is in short supply. Therefore, this system has broad market prospects and is becoming a sunrise industry in the fire protection field.

  1.2. Design basis of fire door monitoring system

  National Standard of the People's Republic of China GB29364-2012 "Fire Door Monitor"

  National Standard of the People's Republic of China GB50116-2013 "Design Specification for Automatic Fire Alarm System"

  National Standard of the People's Republic of China GB50016-2014 "Code for Fire Protection of Building Design"

  Public Security Industry Standard of the People's Republic of China GA93-2004 "Fire Door Closer"

  1.3. Introduction to AFRD fire door monitoring system

  The AFRD fire door monitoring system centrally controls the working status of each terminal device, namely the electric door closer and the electromagnetic release device, and displays the opening, closing and fault status of the fire door of the evacuation channel, and displays the fault signals such as open circuit and short circuit of the terminal device in real time. The system uses the fire two bus to connect the monitoring modules with communication functions. When the terminal equipment is short-circuited or disconnected, the fire door monitor can send out an alarm signal, can indicate the alarm part and save the alarm information, which guarantees the maximum protection. Electrical safety reliability.

  The AFRD fire door monitoring system adopts centralized power supply mode, and the on-site monitoring module uses DC24V safe voltage power supply to effectively ensure the stability and safety of the system. At present, it is widely used in airports, rail transit, tunnels, passenger transportation hubs, hospitals, schools, gymnasiums, exhibition halls, star-rated hotels, high-end commercial buildings and other places.

  2.AFRD100/B fire door monitor

  2.1 Product Overview

  The fire door monitor is the host of the fire door monitoring system. The monitor is linked with the host of the automatic fire alarm system. In the event of a fire, the fire can spread according to the direction of the smoke, and the control command is quickly issued. The command is issued to each terminal through the bus to control the opening and closing state of the fire door. Fire source.

  2.2 Product Features

  It is equipped with a host computer, regional extension, field control and other devices to flexibly build a large-capacity monitoring system;

  The output loop can be extended by regional extensions to accommodate complex and variable modern buildings;

  Adopt centralized power supply mode to provide stable and reliable DC24V voltage for the system;

  Built-in backup power supply, insufficient main power, automatic backup of standby power, effectively ensuring reliable operation of the system;

  Linked with the fire alarm system, once the fire signal is issued, immediately close the normally open fire door;

  Real-time monitoring of the working status of the fire door in the area, and display information such as fault alarms.

  2.3 Product parameters




  2.4 monitor panel component layout and function description



  2.5 Software Monitoring Screen




  2.6 wiring diagram




  3.AFRD-QYFJ regional extension

  3.1. Product Overview

  The regional extension is a local control device of the fire door monitoring system. It can effectively monitor the fire door device in the partial partition. Its own state information can be uploaded to the monitoring host through the bus, which extends the communication distance of the monitor and expands the monitoring terminal. quantity.

  3.2. Product characteristics

  The regional extension can monitor the opening and closing status and fault information of the fire door and feed back to the fire door monitor;

  Accept the instructions of the fire door monitor and interlock the normally open fire door;

  Provides a stable and reliable DC24V safety voltage for system components in the area;

  On-site cancellation of the anti-power supply for the working power supply, flexible construction of a large-capacity fire door monitoring system;

  Built-in backup power supply, automatic switching between main and standby power supplies, effectively ensuring reliable operation of the system;

  The body is small and flexible, and the installation is convenient.

  3.3. Product parameters

  3.4. Panel original layout and function description



  3.5. Dimensions and wiring diagram



  4.AFRD-DY centralized power supply

  4.1. Product Overview

  The centralized power supply is a standby centralized emergency power supply device installed in the building. When the emergency state or the monitoring distance is too far, the fire door monitoring module can be powered urgently to ensure the normal operation of the fire door monitoring system.

  4.2. Product characteristics

  Provides a stable and reliable DC24V safety voltage for system components in the area;

  On-site cancellation of the anti-power supply for the working power supply, flexible construction of a large-capacity fire door monitoring system;

  Built-in backup power supply, automatic switching between main and standby power supplies, effectively ensuring reliable operation of the system;

  The body is small and flexible, and the installation is convenient.

  4.3. Product parameters



  4.4. Panel original layout and function description



  4.5. Dimensions and wiring diagram



  5. List of other components of fire door monitoring system


  Note:

  (1) The normally open fire door can be selected according to the location of the fire door and the opening requirements.

  a: ordinary mechanical door closer ++ electromagnetic release + door magnetic switch + fire door monitoring module;

  b: the way of the fire door closer + door magnetic switch + fire door monitoring module;

  In any case, the fire door status can be uploaded to the fire door monitor through the fire door monitoring module, and the normally open fire door is closed when the fire occurs;

  (2) When setting the normally open fire door, it is necessary to ensure the power supply of the electromagnetic door suction or electric door closer (the power consumption is 80mA);

  (3) The normally closed fire door only needs to upload the fire door state to the controller through the fire door monitoring module through the magnetic switch.

  5.1.AFRD fire door monitoring module

  5.1.1.AFRD-CK1/CK2 normally open single/double fire door monitoring module


  5.1.1.1. Product Overview

  It is used to monitor the working status of the normally open single/double fire door and feed back its status information to the monitor. It can also transmit the command of the monitor to the electromagnetic release, electric door closer or door magnetic switch through the bus.

  5.1.1.2. Product characteristics

  Monitor the opening and closing status and fault signal of the fire door;

  Provides DC24V power for electric door closers and electromagnetic dischargers and receives feedback signals;

  Monitor the working state of the magnetic switch;

  With self-test function, it will emit a light alarm when it fails, and upload it to the fire door monitor;

  With remote communication function, it can feedback its working status to the fire door monitor;

  The shape is exquisite and compact, and the installation is extremely convenient.

  5.1.1.3. Product parameters


  5.1.1.4. Dimensional drawing

  5.1.1.5. Terminal block diagram

  5.1.2.AFRD-CB1/2 normally closed single / double fire door monitoring module


  5.1.2.1. Product Overview

  It is used to monitor the working status of normally closed single/double fire doors and feed back its status information to the monitor.

  5.1.2.2. Product characteristics

  · Monitor the opening and closing status and fault signal of the fire door;

  · With self-test function, it will emit a light alarm when it fails, and upload it to the fire door monitor;

  · With remote communication function, it can feedback its working status to the fire door monitor;

  · Beautiful and compact, it is extremely easy to install.

  5.1.2.3. Product parameters


  5.1.2.4. Dimensional drawing

  5.1.2.5. Terminal block diagram


 

  5.2.AFRD-MC magnetic switch


  5.2.1. Product Overview

  A device for monitoring the opening and closing state of a fire door and feeding back its status information to the fire door monitor.

  5.2.2. Product Features

  · It is used to monitor the opening and closing status and fault information of the fire door, and timely feedback to the fire door field control device;

  · Zinc alloy casing, stainless steel armor cable, beautiful appearance;

  · Beautiful and compact, it is extremely easy to install.

  5.2.3. Product parameters


  5.2.4. Dimensions.


  5.3.AFRD-BMQ electric door closer

  5.3.1. Product Overview

  It can receive the commands transmitted by the fire door monitoring module, and after receiving the command, close the fire door in the open state and feed back its status information to the electric device of the fire door monitor.

  5.3.2 Product characteristics

  Passed the fire type inspection with the AFRD100/B fire door monitor;

  · Automatically power off and close the door after accepting the door closing command;

  · Feedback on the opening and closing status and fault information of the fire door;

  · It can provide a variety of door closers, using 65kg, 85kg, 120kg, 180kg door weight fire doors;

  · A variety of mounting methods are available for different fire doors.

  · Working voltage: DC24V

  · Working current: 80mA

  · Closing method: usually have electricity, power off and close

  5.3.3. Product parameters


  5.3.4. Dimensions


  5.4.AFRD-DC Electromagnetic Releaser

  5.4.1. Product Overview

  It is used to keep the normally open fire door open, release the fire door to close after receiving the instruction of the monitoring module, and feed back its own state information to the electric device of the monitor, wherein the part with communication function is installed on the wall On the surface, the non-communication function is installed on the door.

  5.4.2. Product Features

  · Passed the fire type inspection with the AFRD100/B fire door monitor;

  · Simple mechanical structure, reliable electromagnetic principle, low-voltage micro-current operation, and greatly prolonged service life;

  · With universal adjustment suction plate, the installation is flexible and convenient;

  · Optional special glass door sills for large commercial fire protection needs.

  · Working voltage: DC24V

  · Working current: 80mA

  · Closing method: usually have electricity, power off and close

  5.4.3. Product parameters



  5.4.4. Dimensions


  6. Fire door monitoring system system networking.

  Remarks:

  1 When the number of points in the fire door monitoring system is large, regional sub-area monitoring can be used;

  2 If the monitoring distance is far, the centralized power supply can be used to extend the power supply distance;

  3 If there are fewer points, you can use the communication line to directly supply power to the monitoring terminal. If the distance is still far away, you can add concentrated power and extend the power supply.


上一篇:Fire emergency lighting and evacuation indication system
下一篇:AFPM type fire equipment power monitoring system
?

版权所有金沙平台 沪ICP备18001305号-7

咨询热线:021-69157502  手机:187-0211-2013

传真:021-69158302  地址:上海市嘉定区育绿路253号

主要销售地区:上海,北京,广东,山东

公司自成立以来一直专注于用户端智能电力仪表的研发应用、生产和销售,致力于为用户提供电能质量治理、电能分项计量、
电气火灾监控系统包括多用户计量箱、电气火灾监控、智能照明控制、能耗监测系统、预付费电力系统等   网站地图-XML